Wood frame wall r value for wood frame walls the minimum r value is 13 in zones 1 4.
Minimum wall insulation r value.
Or component performance alternative of section c402 1 5 roof solar reflectance and thermal emittance fenestration in building envelope.
R value based method of section c402 1 3 u c and f factor based method of section c402 1 4.
If structural sheathing covers 40 or less of the exterior continuous insulation r value shall be permitted to be reduced by no more than r 3 in the locations where structural sheathing is used to maintain a consistent total sheathing thickness.
High performance attics prescriptive attic options climate zone hvac duct insulation leakage radiant barrier.
Recommended home insulation r values.
The higher the r value the better the thermal performance of the insulation.
While wall insulation is limited by the width of the studs different materials provide higher or lower r values.
Typical recommendations for exterior walls are r 13 to r 23 while r 30 r 38 and r 49 are common for ceilings and attic spaces.
New wall or walls separating a sunroom from conditioned space shall meet the building thermal envelope requirements.
See the department of energy s doe ranges for recommended levels of insulation below.
Zones 5 and 6 have a requirement of 20 and 7 and 8 are at 21.
Basement walls require a minimum of either r 10 continuous or r 13 batted insulation.
Fiberglass batts for standard 2 4 walls are now available in low medium and high density products that range from r 11 to r 15.
Zones 6 7 and 8 have a value requirement of 49.
The table below shows what levels of insulation are cost effective for different climates and.
These r values are a sum meaning this should be the total r value once you add up the entire depth of insulation.
Insulation level are specified by r value.
Specific insulation requirements of section c402 2 thermal requirements of either.
For example if you have a type of insulation that has an r value of r 5 per inch of thickness you will need a depth of 6 inches of this insulation installed in your attic to reach r 30 if you live in zones 2 or 3.
That means if you used foam it green closed cell which is r 7 per inch it s r value for a 3 5 deep wall cavity would be r 24 5.
Include qii in the contractor scope as a hers rater will be inspecting the work.
The minimum ceiling insulation r values shall be r 24 in zones 5 to 7.
Depending on where you live and the part of your home you re insulating walls crawlspace attic etc you ll need a different r value.
The minimum wall r value shall be r 13 in all zones.
Quality insulation installation qii is now a prescriptive requirement.