Extended set is the same as mk 10 hb except this product can be left unattended in the delivery system for up to 4 days.
Monocoat fire proofing.
The minimum average density shall be that required by the manufacturer listed in the ul fire resistance directory for each rating indicated icbo evaluation report as required by the authority having jurisdiction or minimum average 15 lbs ft3 240 kg m3 whichever is greater.
Patching material for patching monokote mk 5 mk 6 and mk 10 products that when applied as directed will maintain the original fire rating of the steel member.
It has been developed by grace construction products to meet specialty commercial and industrial fireproofing patching requirements.
Examples of afp include the kicking on of a sprinkler system or a staff member using a fire extinguisher to try to put out a small blaze.
Monokote fireproofing material shall not be used if it contains partially set frozen or caked material.
Active fireproofing afp measures are all of those that require some type of action either triggered by ambient conditions or an individual in order to be effective.
Our process can include using hibar blazesheild monokote monoglass or k 13 sprayed on thermal and acoustical insulation and hilti or sti firestopping products.
Monokote fireproofing backed by a global reputation is a life safety product designed to reduce the rate of temperature rise in steel or concrete in the event of a fire.
Monokote mk 1000 hb extended set fireproofing is a single component mill mixed fireproofing plaster cementitious which has a delayed set feature.
Monokoteaccelerator shall be mixed and used according to manufactur ers recommendations.
Monokote patching compound is a mill.
Monokote patching compound is a mill mixed plaster cementitious fireproofing material that can be hand mixed and trowel applied as required for patching and repairs to surfaces.
The minimum average density shall be that required by the manufacturer listed in the ul fire resistance directory for each rating indicated as required by the authority having jurisdiction or minimum average 15 lbs ft 3 240 kg m 3 whichever is greater.
Extended set is the same as mk 1000 hb except this product can be left unattended in the delivery system for up to 4 days.
Monokote fireproofing material shall not be used if it contains partially set frozen or caked material.
The monokote accelerator is injected into the monokote fire proofing at the spray gun.
G monokote is applied directly to the steel at various rates of application which will be job.
Monokote mk 10 hb extended set fireproofing is a single component mill mixed fireproofing plaster cementitious which has a delayed set feature.
Rite way thermal fire specializes in the fireproofing insulation and firestopping for commercial applications.